Fiber, and all materials for industrial floors
+7 (863) 296-47-79
Write e-mail
Steel hooked ends fiber hendix

Steel hooked ends fiber Hendix 1/50

СТО 71915393-ТУ 106-2011; EN 14889-1:2006
890 USD
price per ton

Recommended scope of application

All types of industrial floors
(cut joint, jointless, pile supported)

Roads, strip and single foundations

More

Steel hooked ends fiber Hendix Prime 75/52м

СТО 71915393-ТУ 106-2011; EN 14889-1:2006
1020 USD
price per ton

Recommended scope of application

All types of industrial floors
(cut joint, jointless, pile supported, screeds).

Load bearing constructions (foundation rafts,
elevated slabs supported by columns and/or walls).

Roads, reinforced concrete constructions,
strip and single foundations.

More

Steel hooked ends fiber Hendix 1/50

СТО 71915393-ТУ 106-2011; EN 14889-1:2006

Description

Steel wire fiber Hendix 1/50 with hooked ends, randomly distributed in the concrete can reduce or even replace traditional rebar and welded mesh reinforcement.It can be applied in industrial floors, roads, strip foundation, road surfacing, bridges and other constructions with standard structural demands.

Advantages

Hendix 1/50 fiber provide a good performance of reinforcement effect in the concrete while they are easy dosable with a low tendency to form clumps when added to the concrete mixture.

Recommended scope of application

  • All types of industrial floors (cut joint, jointless, pile supported)
  • Roads, strip and single foundations

Fiber dimensions and mechanical properties

Fiber diameter, mm Fiber length, mm Hooked ends length, mm Hook height, mm Bend angle Tensile strength, MPa Modulus of elasticity, MPа Number of fibers per 1 kg, pcs.
1.0±0,04 50±2,0 2.0-1.0/+2.0 2.1+0.5/-0.0 40° ±5° 1150 ≥ 190000 ~ 3 240

Packaging

  • Corrugated cardboard boxes per 25 kg. Fiber in a box is placed oriented in the same direction for easy dosing. Number of boxes on one pallet – 48 pcs. Weight of one pallet – 1200 kg

Technical standard documentation

  • Code of regulations 52-104-2006 “Steel fiber reinforced concrete structures”.
  • EN 1992-1-1 Design of concrete structures. – Part 1-1: General rules and rules for buildings
  • DIN EN 1045-1 Concrete reinforced and prestressed concrete structures - Part 1: Design and construction.
  • DAffStb Directive “Steel fiber reinforced concrete” 03/2010 (as a supplement to DIN EN 1045 for concrete structures)
  • TR34 Concrete industrial ground floors. A guide to their design and construction. (UK Concrete society CS).
  • TR550 Industrial floors design (UK Concrete society CS).
Request for related information Hendrix 1/50

Hendix prime 75/52 — hooked ends fiber

СТО 71915393-ТУ 106-2011; EN 14889-1:2006

Description

Steel wire fiber Hendix Prime 75/52 with hooked ends, randomly distributed in the concrete can reduce or even replace traditional rebar and welded mesh reinforcement. It can be applied both in standard applications of steel fiber reinforced concrete, and in load bearing concrete structures (foundations, walls, ceiling slabs, pile supported floors, bridge constructions, reinforced concrete constructions).

Advantages

Hendix Prime 75/52 fiber have an improved length/diameter ratio, a big amount of fiber per kg and therewith a good saturation of fiber in the concrete matrix and increased tensile strength for high performance. Due to this the dosing may be reduced by 20-30% compared to fiber Hendix 1/50 in standard applications of steel fiber reinforced concrete, as well as using this fiber to reinforce load bearing concrete structures (foundations, ceiling slabs)

Recommended scope of application

  • All types of industrial floors (cut joint, jointless, pile supported, screeds).
  • Load bearing constructions (foundation rafts, elevated slabs supported by columns and/or walls).
  • Roads, reinforced concrete constructions, strip and single foundations.

Fiber dimensions and mechanical properties

Fiber diameter, mm Fiber length, mm Hooked ends length, mm Hook height, mm Bend angle Tensile strength, MPa Modulus of elasticity, MPа Number of fibers per 1 kg, pcs.
0.75±0,04 52±2,0 2.0-1.0/+2.0 2.1+0.5/-0.0 40° ±5° 1500 ≥ 190000 ~ 5 545

Packaging

  • Corrugated cardboard boxes per 25 kg. Fiber in a box is placed oriented in the same direction for easy dosing. Number of boxes on one pallet – 48 pcs. Weight of one pallet – 1200 kg

Technical standard documentation

  • EN 1992-1-1 Design of concrete structures. – Part 1-1: General rules and rules for buildings
  • DIN EN 1045-1 Concrete reinforced and prestressed concrete structures - Part 1: Design and construction.
  • DAffStb Directive “Steel fiber reinforced concrete” 03/2010 (as a supplement to DIN EN 1045 for concrete structures)
  • TR34 Concrete industrial ground floors. A guide to their design and construction. (UK Concrete society CS).
  • TR550 Industrial floors design (UK Concrete society CS).
Request for related information Hendix Prime 75/52

Contact us

Should you require any further information about of our
products, terms and conditions, fill out the form, please:
We are available on week days from 8 a.m. to 6 p.m. Moscow time (UTC+03:00).
We will contact you in the shortest time upon receipt your request.